Solenoid Auto Tester &Cleaner
TEKON-200A/300A
Solenoid Auto Tester &Cleaner
User’s Manual
(Auto Test &Cleaner Equipment )
Solenoid Auto Tester &Cleaner Manual
Table of Contents
1. Equipment Instruction
2. Caution
3. Specifications
4. Packing Components
5. Test &Cleaner Method
6. A/S
1. Equipment Introduction
TEKON-200A/300A Solenoid Tester &Cleaner is the product that realized the function to WARNING_SQL_INJECTIONthe Good and the N.G automatically according to the standard of the data which compare and analyze the good Solenoid and that can clarify the selection of Good and N.G better than the existing product.
In addition,this is the product that can realize the cleansing and the verification at the same time because Solenoid Cleaner(1CH/200A,8CH/300A) is added.
2. Caution
1. Don't WARNING_SQL_INJECTIONthis product.
2. Turn off after using it.
3. Don't short the Alligator Clip of Output terminal.
4. Don't give shock on the face of LCD.
5. When using this,don't use it vertically..
6. When working Function S/W,don't use something sharp like an awl.
7. When testing Solenoid Valve for 5V,don't test in 12V. (Please confirm the front of 5V LED Light.)
3. Specifications
4. Packing List
5. Test Method
Display Content(Function) Deion
① Counter Set-Up:1(Manual)/10/20/30 times for automatic function is
possible. At this time,Good/N.G Counter at the bottom of the screen
is marked as the total of the set point.
② Division Set-Up:It is possible to set the maximum current vertically.
It is possible to set according to the size of the waveform.
You can adjust the set-up by 1~5A. Please set the waveform nicely.
③ The range of Error: You can adjust the range of error which can
decide the Good/N.G. You can adjust the error by 1~5%.
④ Store Function:You can store by 50. (Store the good Solenoid
waveform. When you test, take out the waveform and compare the
parts which you want to measure. It then,you can decide the
good/N.G).
⑤ Good Function:Count just the number of Pass at the Counter Set
point of ①.
⑥ N.G Function:Count just the number of Fault at the Counter Set-
point of ①.
⑦ It is stored Solenoid Current Waveform.
⑧ Resistance Value:It is the measurement resistance value when
Solenoid is tested.
⑨ Solenoid Test Max. Current:It is the maximum current of waveform
when Solenoid is tested.
5-1. Solenoid Valve Test Method
1) After turning on the Power S/W,WARNING_SQL_INJECTIONthe measuring by using
the Function Key (Up/Down) and then press the Enter Key.
2) WARNING_SQL_INJECTION5V/12V with Toggle S/W of Rear Panel.
3) Use the Function Key and adjust like the screen of the Next page.
Then,if you turn on the Test Key,the test will start.
(It is comfortable to use it after storing the good Solenoid because
the standard is different according to the each manufacturer and
model.)
4) Adjust Count,Div.,Error,Store with Function Key.
5-1. Solenoid Valve Test Method
4) When the Solenoid Test completes, the measured Graph displays
on the left side like the following screen. On the right of the bottom,
the value the same as the number of test count displays( Good or N.G).
5) At this time,in the case of N.G due to out of the standard,
the count displays on the N.G of the result screen and in case of Good,
the value displays on the Good.
5-2. Solenoid Valve Cleaner Method
1) After turning on the Power S/W,WARNING_SQL_INJECTIONthe Cleaner by using
the Function Key (Up/Down) and then press the Enter Key while
using the measuring,if you want to set Cleaner,press Mode Key
on the right for 2~3 seconds. Then you can use the first menu
screen. At this time,you can set the cleaner by using up/down
Switch.
2) The cleaning starts when the test key is on after setting like the
following with Function Key. (200A ;1CH,300A ; 8CH)
3) Set Duty,Cycle,Time with Function Key.
5-2. Solenoid Valve Cleaner Method
1) Mode :Setting A ( ON Time 25ms Fix)
① Cycle: Setting of 50ms,100ms,150ms,200ms,250ms,300m
is possible.
②Time: By 5min,10min,20min,30min is possible.
2) Mode :Setting B (Duty Ratio 1 : 1)
① ON/Off Time is sett equally.
② Setting of Time and Cycle is the same as Mode A.
6. A/S
1) warranty period :1 year after receipt product
Solenoid Auto Tester &Cleaner
TEKON-200A/300A Solenoid Tester & Cleaner is the product that realized the function to WARNING_SQL_INJECTIONthe Good and the N.G automatically according to the standard of the data which compare and analyze the good Solenoid and that can clarify the selection of Good and N.G better than the existing product.
Specifications
판매사 정보
판매사 | 주식회사 테크온 | 홈페이지 | http://www.tekon.co.kr |
---|---|---|---|
구매문의 | 070-7726-6030 | 이메일 | jd@tekon.co.kr |
사업장소재지 | 경기도 부천시 송내대로 388 (약대동, 부천테크노파크2단지) 203-702 |
판매사 다른 상품
같은 카테고리 상품
판매사 정보
상호/대표자 | 주식회사 테크온 / 김재동 | 사업자등록번호 | 122-86-39186 | |
---|---|---|---|---|
사업장소재지 | 경기도 부천시 송내대로 388 (약대동, 부천테크노파크2단지) 203-702 | |||
통신판매업신고번호 |
상품고시 품목별정보
상품정보제공고시
품명 및 모델명 | Solenoid valve test & cleaner 솔레노이드밸브 테스터 / Solenoid valve test & cleaner, 솔레노이드밸브 테스터 |
---|---|
제조국 또는 원산지 | |
제조사/판매사 | 주식회사 테크온 |
구매문의 | 070-7726-6030 |
상품상태 | 신제품 |
A/S정보 | 가능 |
제조년월 | |
부가가치세 | 가세 |
배송/교환/반품 안내
AS 관련 문의,소비자 피해보상 또는 불만 처리는”판매자 정보”를 참고 하시기 바랍니다.
배송안내 지역,날씨 상황에 따라 달라질 수 있습니다. |
|
---|---|
반품/교환안내 반품/교환에 관한 일반적인 사항은 판매사 제시 사항보다 관례법령이 우선 합니다. |
|
반품/교환 가능기간 먼저 판매자와 연락하여 반품사유,택배사,배송비,반품주소 등을 협의 후에 상품을 발송해 주십시오. |
|
반품/교환 불가사유 |
|